Deviation is a common issue in the operation of belt conveyors, which can be attributed to various factors such as non-perpendicular roller axes, skewed roller sets, uneven feeding loads, curvature of the belt itself, or misaligned joints. In terms of installation and maintenance, the levelness of the frame is a quantifiable control point. Technical documentation suggests regularly calibrating the levelness of the conveyor frame to ensure deviations are controlled within ≤0.5 mm/m, and adjusting the roller position accordingly to maintain consistency between the centerline of the belt and the centerline of the frame. For minor deviations, self-aligning rollers can play a corrective role; however, if the deviation stems from inaccurate frame benchmarking or misaligned joints, adjusting only with rollers often fails to fundamentally resolve the issue. In routine maintenance, incorporating levelness inspection and roller cleaning as fixed items is more feasible than passively correcting deviations after they occur.